Overhauling the Mitsubishi purifier selfjector bowl involves a series of meticulous steps that ensure thorough cleaning and reassembly. Here’s a breakdown of the overhauling procedure:
Preparation for Overhauling
Before beginning the overhauling process, ensure that the purifier is stopped, and all safety measures are in place. Lock out and tag out (LOTO) the power supply to prevent accidental startup. Prepare all necessary tools, spare parts, and cleaning materials, including lint-free cloths, lubricants, and solvent. It’s also essential to have the purifier’s manual on hand for reference, as it contains specific details related to your purifier model.Disassembly of the Purifier Bowl
Start by carefully removing the purifier bowl from the housing. Note the positions of each part for accurate reassembly later. Loosen and remove the lock ring or locking nut, followed by the upper and lower parts of the bowl. Use proper tools and follow the recommended torque specifications to avoid damaging any components. Once the bowl is disassembled, inspect the individual components, including the disc stack, bowl hood, and distribution holes, for wear or damage.Cleaning and Inspection of Parts
Clean each component thoroughly using a recommended solvent or cleaning agent. Scrub the disc stack, bowl hood, and other parts to remove oil, sludge, and other contaminants that can hinder performance. Inspect all components, especially the seals, O-rings, and gaskets, for signs of wear or damage and replace any worn parts to prevent future leaks and ensure the purifier’s efficiency. A clean and well-maintained disc stack is crucial for optimal purification performance.Reassembly of the Purifier Bowl
Carefully reassemble the bowl, ensuring each component is placed in its correct position as per the manual’s instructions. Align the disc stack accurately and secure the locking nut or lock ring with the correct torque specifications. Lubricate the moving parts as needed to facilitate smooth operation. Proper alignment and assembly are essential to prevent vibrations and ensure that the purifier runs efficiently.Testing and Final Inspection
Once the purifier bowl is reassembled, perform a test run to verify that everything is functioning correctly. Monitor the purifier for abnormal noises, leaks, or vibrations, and confirm that the purified oil output meets quality standards. Regularly inspecting and testing after overhauling helps identify any issues early and ensures reliable operation.